Environmental Quality, Drinking Water

R309-150-6

Physical Facilities

 

NOTICE OF PROPOSED RULE

DAR File No.: 28417
Filed: 12/15/2005, 01:23
Received by: NL

 

RULE ANALYSIS

Purpose of the rule or reason for the change:

The reason for the change is to change wording to refer to minimum water pressures described in Section R309-105-9. (DAR NOTE: The proposed amendment to Section R309-105-9 is under DAR No. 28416 in this issue.)

 

Summary of the rule or change:

The change makes reference to Section R309-105-9 so that minimum pressures associated with existing systems will not be confused with minimum pressures required for new Public Water Systems designed and constructed after March 1, 2006.

 

State statutory or constitutional authorization for this rule:

Section 19-4-104

 

Anticipated cost or savings to:

the state budget:

None--Since this amendment only clarifies this portion of rule and the additional water pressure requirements for new Public Water Systems, it will not require additional personnel or other funds from the state budget

 

local governments:

Little to None--Most, if not all, well functioning Public Water Systems operated by local government currently meet or exceed the current minimum water pressure minimums, as well as the proposed additional minimums. The design of new Public Water Systems will only require initial planning concerning storage location and distribution pipeline sizing which should not add significant cost or time.

 

other persons:

Little to None--Most engineering companies currently look to typical textbook design standards, as well as standards of other agencies such as the American Water Works Association (AWWA), the American Society of Civil Engineers (ASCE), and other nearby states when designing Public Water Systems so there should not be any additional cost or time involved.

 

Compliance costs for affected persons:

New Public Water Systems designed and constructed after March 1, 2006, should not see any costs over and above that if their system were designed with the typical capacity for anticipated growth and expansion. Some increased cost may be expected if storage tank location for adequate pressure requires additional length of transmission line.

 

Comments by the department head on the fiscal impact the rule may have on businesses:

The department agrees that the proposed changes to this rule will have little to no detrimental impact on existing water systems nor on new public water systems. Dianne R. Nielson, Executive Director

 

The full text of this rule may be inspected, during regular business hours, at the Division of Administrative Rules, or at:

Environmental Quality
Drinking Water
150 N 1950 W
SALT LAKE CITY UT 84116-3085

 

Direct questions regarding this rule to:

Bill Birkes at the above address, by phone at 801-536-4201, by FAX at 801-536-4211, or by Internet E-mail at bbirkes@utah.gov

 

Interested persons may present their views on this rule by submitting written comments to the address above no later than 5:00 p.m. on:

01/31/2006

 

This rule may become effective on:

02/01/2006

 

Authorized by:

Kevin Brown, Director

 

 

RULE TEXT

R309. Environmental Quality, Drinking Water.

R309-150. Water System Rating Criteria.

R309-150-6. Physical Facilities.

All points assessed to public water systems via this subsection are based upon violation of R309-113 and R309-200 through R309-211. These points shall be assessed and updated upon notification of the Executive Secretary and shall remain until the violation or deficiency no longer exists.

(1) New Source Approval:

(a) Use of an unapproved source shall be assessed 150 points.

(2) Surface Water Diversion Structures and Impoundments:

(a) For each surface water intake structure that does not allow for withdrawal of water from more than one level if quality significantly varies with depth 2 points shall be assessed.

(b) Where no facilities exist for release (wasting) of less desirable water held in storage 2 points shall be assessed.

(c) Where the diversion facilities do not minimize frazil ice formation by holding intake velocities to less than 0.5 feet per second 2 points shall be assessed.

(d) Where diversion facilities are not adequately protected from damage by ice buildup 2 points shall be assessed.

(e) Where diversion facilities are not capable of keeping large quantities of fish or debris from entering the intake 2 points shall be assessed.

(f) Where reservoirs have not had brush and trees removed to the high water level 2 points shall be assessed.

(g) Where reservoir watershed management has not provided adequate precautions to limit nutrient loading 10 points shall be assessed.

(3) Well Sources

(a) For each well which is not equipped with a sanitary seal, or has any unsealed opening into the well casing 50 points shall be assessed.

(b) For each well which does not utilize food grade mineral oil for pump lubrication 25 points shall be assessed.

(c) For each well casing which does not terminate at least 12 inches above the pumphouse floor, 18 inches above ground, and/or five feet above the highest flood elevation, or is not fitted with an acceptable pitless adaptor 1 to 20 points shall be assessed based upon whether the adjacent land slopes toward or away from the wellhead; the integrity of the cement surrounding the wellhead and other factors that would jeopardize the integrity of the wellhead seal.

(d) For each well casing vent which is not properly covered with a No. 14 mesh screen 5 points shall be assessed.

(e) For each well which has discharge piping that is not properly equipped with 1) a smooth nosed sampling tap 2) check valve 3) pressure gauge 4) means of measuring flow and 5) shutoff valve 1 to 5 points shall be assessed depending upon the number of the above components that are present.

(f) For each well where there is no means to release trapped air from the discharge piping 5 points shall be assessed.

(g) For each well house which does not have a drain-to-daylight installed 5 points shall be assessed.

(4) Spring Sources:

(a) For each spring source which allows surface water to stand or pond upon the spring collection area (within 50 feet from collection devices) 1 to 20 points shall be assessed. The number of points shall be based upon the size and extent of the ponding; the possible source (rainfall or incomplete collection); or the presence of moss or other indicators of long term presence of standing water.

(b) For each spring area which does not have a minimum of ten feet of relative impervious soil or an acceptable liner 10 points shall be assessed.

(c) For each spring area that has deep rooted vegetation within the fenced collection area 10 points shall be assessed.

(d) For each spring area that has deep rooted vegetation interfering with the spring collection 10 points shall be assessed.

(e) For each spring which does not have a proper collection/junction box; and does not have the following: a proper shoebox lid, gasket, No. 14 mesh screen on the vent line and lock; 1 to 25 points shall be assessed. The number of points shall be determined by the number of the above items that are present.

(f) For each spring collection area without a proper fence (unless the spring is located in a remote area where no grazing or public access is possible as specified in R309-106(5)(e)) 10 points shall be assessed.

(g) For each spring collection area that does not have a diversion channel capable of diverting surface water away from the collection area 5 points shall be assessed.

(h) For each spring system which does not have a permanent flow measuring device 5 points shall be assessed.

(i) For each spring area with an overflow/drain that is not properly screened with a No. 4 mesh screen or does not have adequate freefall (12 to 24 inches) between the drain invert and the surrounding ground 5 to 10 points shall be assessed. The number of points shall be based upon the presence of a screen and the slope of the ground surrounding the overflow/drain outlet.

(5) Disinfection by gaseous chlorine:

(a) A chlorinated water system that does not maintain a detectable chlorine residual throughout the distribution system shall be assessed 10 points.

(b) An improperly heated, lighted, and vented chlorinator building shall be assessed 2 points.

(c) A chlorinated water system that does not have a test kit to measure chlorine residual shall be assessed 2 points.

(d) A chlorinated water system that does not have a cylinder wrench located on the yoke valve shall be assessed 2 points.

(e) A chlorinated water system that utilizes one ton cylinders and does not have proper chlorine leak detection and repair kit equipment shall be assessed 15 points.

(f) A chlorinated water system that utilizes 150 pound cylinders and does not have proper chlorine leak detection and repair kit equipment shall be assessed 2 points.

(g) A chlorinated water system that does not have chlorine cylinders properly restrained or isolated from operating areas shall be assessed 2 points.

(h) A chlorinated water system that does not have a feeder vent properly vented to the outside and screened with a No. 14 mesh screen shall be assessed 2 points.

(i) A chlorinated water system without means to measure chlorine feed and cylinder usage shall be assessed 2 points.

(j) A chlorinated water system without access to a properly stored gas mask or stores a gas mask in the same room where chlorine gas is handled shall be assessed 5 points.

(k) A chlorination station without a means of measuring the volume of water treated shall be assessed 2 points.

(6) Disinfection by liquid hypochlorite:

(a) A chlorinated water system that does not maintain a detectable chlorine residual throughout the distribution system shall be assessed 10 points.

(b) An improperly housed and secured hypochlorinator station shall be assessed 2 points.

(c) A chlorinated water system that does not have a test kit to measure chlorine residual shall be assessed 2 points.

(d) A chlorinated water system that does not maintain a spare parts repair kit for the positive displacement pumps shall be assessed 2 points.

(e) A hypochlorination station without a means of measuring the volume of water treated shall be assessed 2 points.

(7) Storage:

(a) A water system with an uncovered finished water storage reservoir shall immediately be assessed a rating of not approved.

(b) For each storage reservoir access that is not an overlapping (shoe box) type lid, locked and is at least 4 inches above the top of the tank 10 points shall be assessed.

(c) For each improperly vented storage reservoir 5 points shall be assessed.

(d) For each storage reservoir overflow that: is not properly screened, is not sloped for drainage, or is connected to a sewer without an appropriate air gap; 5 to 15 points shall be assessed based on the number and severity of the above items that are present.

(e) For each storage reservoir with inadequate or improper means of drainage 2 points shall be assessed.

(f) For each storage reservoir where the roof and sidewalls are not water tight shall be assessed 10 to 50 points based upon the size and number of cracks, the loss of structural integrity and the access of contamination to the drinking water.

(g) For each storage reservoir without an access ladder, or railing where required (elevated tank) 2 points shall be assessed.

(h) For each storage reservoir with internal coatings not in compliance with ANSI/NSF standard 61 30 points shall be assessed.

(8) Distribution System:

(a) A water system which fails to provide at least [20 psi]the water pressure as required in R309-105-9 at all times and at all locations within the distribution system [during peak instantaneous flow conditions ]shall be assessed 50 points.

(b) A water system using unapproved pipe and materials shall be assessed 30 points.

(c) A water system with pipelines installed improperly without adequate clearance or separation from sewer lines shall be assessed 30 points.

(d) For each air vacuum release valve which is not properly screened and turned down 2 points shall be assessed up to a maximum of 20 points per system.

(e) For each flooded air vacuum release valve chamber 20 points shall be assessed up to a maximum of 50 points per system.

(9) Quantity requirements

(a) A water system which does not have sufficient source capacity to meet peak daily and average yearly flow requirements shall be assessed from 5 to 50 points. The number of points shall be based upon the severity of the shortage including the number of times and duration of water outages or low pressure.

(b) A water system which does not have sufficient storage capacity to meet average daily flow requirements shall be assessed from 5 to 50 points. The number of points shall be based upon the severity of the shortage including the number of times and duration of water outages.

 

KEY: drinking water, environmental protection, water system rating, administrative procedures

[January 4, 2001]2006

Notice of Continuation May 16, 2005

19-4-104

63-46b-4

 

 

 

 

ADDITIONAL INFORMATION

PLEASE NOTE:

  • Text to be deleted is struck through and surrounded by brackets (e.g., [example]). Text to be added is underlined (e.g., example). Some browsers may not depict some or any of these attributes on the screen or when the document is printed.
  • Please see the DISCLAIMER regarding information available from state web pages.
 

For questions regarding the content or application of this rule, please contact Bill Birkes at the above address, by phone at 801-536-4201, by FAX at 801-536-4211, or by Internet E-mail at bbirkes@utah.gov

For questions about the rulemaking process, please contact the Division of Administrative Rules (801-538-3764). Please Note: The Division of Administrative Rules is NOT able to answer questions about the content or application of these administrative rules.

Last modified:  12/28/2005 2:39 PM