(a) The purpose of R315-8 is to establish minimum State of Utah standards which define the acceptable management of hazardous waste.
(b) The standards in R315-8 apply to owners and operators of all facilities which treat, store, or dispose of hazardous waste, except as specifically provided otherwise in R315-8 or R315-2.
(c) The requirements of R315-8 apply to a person disposing of hazardous waste by means of underground injection subject to a permit issued under the Underground Injection Control (UIC) program approved or promulgated under the Safe Drinking Water Act only to the extent they are required by R315-3. R315-8 applies to the above-ground treatment or storage of hazardous waste before it is injected underground.
(d) The requirements of R315-8 apply to the owner or operator of a POTW which treats, stores, or disposes of hazardous waste only to the extent they are included in a RCRA permit by rule granted to such a person under R315-3.
(e) The requirements of R315-8 do not apply to:
(1) The owner or operator of a state approved facility managing municipal or industrial solid waste, if the only hazardous waste the facility treats, stores, or disposes of is excluded from regulation under R315-2-5, conditionally exempt small quantity generator exemption;
(2) A generator accumulating waste on-site in compliance with R315-5-3.34, which incorporates by reference 40 CFR 262.34;
(3) A farmer disposing of waste pesticides from his own use in compliance with R315-5-7;
(4) The owner or operator of a totally enclosed treatment facility. A totally enclosed treatment facility is a facility for the treatment of hazardous waste which is directly connected to an industrial production process and which is constructed and operated in a manner which prevents the release of any hazardous waste or any constituent thereof into the environment during treatment;
(5) A transporter storing manifested shipments of hazardous waste in containers meeting the requirements of R315-5-3.30 at a transfer facility for a period of ten days or less;
(6)(i) Except as provided in R315-8-1(e)(6)(ii), a person engaged in treatment or containment activities during immediate response to any of the following situations:
(A) A discharge of a hazardous waste;
(B) An imminent and substantial threat of a discharge of hazardous waste; and
(C) A discharge of a material which, when discharged, becomes a hazardous waste.
(ii) An owner or operator of a facility otherwise regulated by R315-8 shall comply with all applicable requirements of R315-8-3 and R315-8-4.
(iii) Any person who is covered by R315-8-1(e)(6)(i), and who continues or initiates hazardous waste treatment or containment activities after the immediate response is over is subject to all applicable requirements of R315-8 and R315-3 for those activities.
(iv) In the case of an explosives or munitions emergency response, if a State or local official acting within the scope of his or her official responsibilities, or an explosives or munitions emergency response specialist, determines that immediate removal of the material or waste is necessary to protect human health or the environment, that official or specialist may authorize the removal of the material or waste by transporters who do not have EPA identification numbers and without the preparation of a manifest. In the case of emergencies involving military munitions, the responding military emergency response specialist's organizational unit shall retain records for three years identifying the dates of the response, the responsible persons responding, the type and description of material addressed, and its disposition.
(7) The owner or operator of an elementary neutralization unit or a wastewater treatment unit as defined in R315-1-1(b), which incorporates by reference 40 CFR 260.10, provided that if the owner or operator is diluting hazardous ignitable (D001) wastes, other than the D001 High TOC Subcategory defined in R315-13, which incorporates by reference 40 CFR 268.40, or reactive (D003) waste, to remove the characteristic before land disposal, the owner/operator shall comply with the requirements set out in R315-8-2.8(b);
(8) The addition of absorbent material to waste in a container, as defined in R315-1, or the addition of waste to absorbent material in a container, provided that these actions occur at the time waste is first placed in the container; and R315-8-2.8(b), R315-8-9.2, and R315-8-9.3 are complied with;
(9) The owner or operator of a facility managing recyclable materials described in R315-2-6, which incorporates by reference 40 CFR 261.6, except to the extent that they are referred to in R315-15 or R315-14-2, which incorporates by reference 40 CFR 266 subpart C, R315-14-5, which incorporates by reference 40 CFR 266 subpart F, R315-14-6, which incorporates by reference 40 CFR 266 subpart G, and R315-14-7, which incorporates by reference 40 CFR 266 subpart H; and
(10) Universal waste handlers and universal waste transporters (as defined in R315-16-1.9), handling the wastes listed below. These handlers are subject to regulation under R315-16, when handling the below listed universal wastes:
(i) Batteries as described in R315-16-1.2;
(ii) Pesticides as described in R315-16-1.3;
(iii) Mercury thermostats as described in R315-16-1.4; and
(iv) Mercury lamps as described in R315-16-1.5.
(f) The requirements of this rule apply to owners or operators of all facilities which treat, store, or dispose of hazardous waste referred to in R315-13, which incorporates by reference 40 CFR 268.
(g) The requirements of R315-8-2 through 8-4 and R315-8-6.12 do not apply to remediation waste management sites. (However, some remediation waste management sites may be a part of a facility that is subject to a traditional hazardous waste permit because the facility is also treating, storing or disposing of hazardous wastes that are not remediation wastes. In these cases, R315-8-2 through 8-4 and R315-8-6.12 do apply to the facility subject to the traditional hazardous waste permit). Instead of the requirements of R315-8-2 through 8-4, owners or operators of remediation waste management sites must:
(1) Obtain an EPA identification number by applying to the Division of Solid and Hazardous Waste using EPA Form 8700-12;
(2) Obtain a detailed chemical and physical analysis of a representative sample of the hazardous remediation waste to be managed at the site. At a minimum, the analysis must contain all of the information which must be known to treat, store, or dispose of the waste according to R315-13, which incorporates by reference 40 CFR 268, and R315-8, and must be kept accurate and up to date;
(3) Prevent people who are unaware of the danger from entering, and minimize the possibility for unauthorized people or livestock to enter onto the active portion of the remediation waste management site, unless the owner or operator can demonstrate to the Executive Secretary that:
(i) Physical contact with the waste, structures, or equipment within the active portion of the remediation waste management site will not injure people or livestock who may enter the active portion of the remediation waste management site; and
(ii) Disturbance of the waste or equipment by people or livestock who enter onto the active portion of the remediation waste management site, will not cause a violation of the requirements of R315-8;
(4) Inspect the remediation waste management site for malfunctions, deterioration, operator errors, and discharges that may be causing, or may lead to, a release of hazardous waste constituents to the environment, or a threat to human health. The owner or operator must conduct these inspections often enough to identify problems in time to correct them before they harm human health or the environment, and must remedy the problem before it leads to a human health or environmental hazard. Where a hazard is imminent or has already occurred, the owner/operator must take remedial action immediately;
(5) Provide personnel with classroom or on-the-job training on how to perform their duties in a way that ensures the remediation waste management site complies with the requirements of R315-8, and on how to respond effectively to emergencies;
(6) Take precautions to prevent accidental ignition or reaction of ignitable or reactive waste, and prevent threats to human health and the environment from ignitable, reactive and incompatible waste;
(7) For remediation waste management sites subject to regulation under R315-8-9 through 8-15, and R315-8-16, which incorporates by reference 40 CFR 264.600 - 603, the owner/operator must design, construct, operate, and maintain a unit within a 100-year floodplain to prevent washout of any hazardous waste by a 100-year flood, unless the owner/operator can meet the demonstration of R315-8-2.9(b);
(8) Not place any non-containerized or bulk liquid hazardous waste in any salt dome formation, salt bed formation, underground mine or cave;
(9) Develop and maintain a construction quality assurance program for all surface impoundments, waste piles and landfill units that are required to comply with R315-8-11.2(c) and (d), R315-8-12.2(c) and (d), and R315-8-14.2(c) and (d) at the remediation waste management site, according to the requirements of R315-8-2.10;
(10) Develop and maintain procedures to prevent accidents and a contingency and emergency plan to control accidents that occur. These procedures must address proper design, construction, maintenance, and operation of remediation waste management units at the site. The goal of the plan must be to minimize the possibility of, and the hazards from a fire, explosion, or any unplanned sudden or non-sudden release of hazardous waste or hazardous waste constituents to air, soil, or surface water that could threaten human health or the environment. The plan must explain specifically how to treat, store, and dispose of the hazardous remediation waste in question, and must be implemented immediately whenever a fire, explosion, or release of hazardous waste or hazardous waste constituents which could threaten human health or the environment;
(11) Designate at least one employee, either on the facility premises or on call (that is, available to respond to an emergency by reaching the facility quickly), to coordinate all emergency response measures. This emergency coordinator must be thoroughly familiar with all aspects of the facility's contingency plan, all operations and activities at the facility, the location and characteristics of waste handled, the location of all records within the facility, and the facility layout. In addition, this person must have the authority to commit the resources needed to carry out the contingency plan;
(12) Develop, maintain and implement a plan to meet the requirements in R315-8-1(g)(2) through (g)(6) and R315-8-1(g)(9) through (g)(10); and
(13) Maintain records documenting compliance with R315-8-1(g)(1) through (g)(12).
1.1 RELATIONSHIP TO INTERIM STATUS STANDARDS
A facility owner or operator who has fully complied with the requirements for interim status--as defined in section 3005(e) of the Federal RCRA Act and regulations under R315-3-7.1 shall comply with the regulations specified in R315-7 in lieu of R315-8, until final administrative disposition of his permit application is made, except as provided under R315-8-21, which incorporates by reference 40 CFR 264.552 and 264.553.
2.1 APPLICABILITY
(a) The rules in this section apply to the owners or operators of all hazardous waste management facilities, except as provided otherwise in R315-8-1(e).
(b) R315-8-2.9(b) applies only to facilities subject to regulation under R315-8-9 through R315-8-15 and R315-8-16, which incorporates by reference 40 CFR 264.600 - 264.603.
2.2 IDENTIFICATION NUMBER
Every facility owner or operator shall obtain an EPA identification number by applying to the Executive Secretary using EPA form 8700-12. Information on obtaining this number can be acquired by contacting the Utah Division of Solid and Hazardous Waste.
2.3 REQUIRED NOTICES
(a)(1) An owner or operator of a facility that has arranged to receive hazardous waste from a foreign source shall notify the Board in writing at least four weeks in advance of the expected date of arrival of these shipments at the facility. A notice of subsequent shipments of the same waste from the same foreign source is not required.
(2) The owner or operator of a recovery facility that has arranged to receive hazardous waste subject to R315-5-8, which incorporates by reference 40 CFR 262, subpart H, shall provide a copy of the tracking document bearing all required signatures to the notifier, to the Division of Solid and Hazardous Waste, P.O. Box 144880, Salt Lake City, Utah, 84114-4880; Office of Enforcement and Compliance Assurance, Office of Compliance, Enforcement Planning, Targeting and Data Division (2222A), Environmental Protection Agency, 401 M St., SW., Washington, DC 20460; and to the competent authorities of all other concerned countries within three working days of receipt of the shipment. The original of the signed tracking document shall be maintained at the facility for at least three years.
(b) An owner or operator of a facility that receives hazardous waste from off-site, except when the owner or operator is also the generator, shall inform the generator in writing that he has the appropriate permit(s) for, and will accept, the waste the generator is shipping. A copy of this written notice shall be retained by the owner or operator as part of the operating record of waste received.
(c) Before transferring ownership or operation of a facility during its operating life, or of a disposal facility during the post-closure care period, the owner or operator shall notify the new owner or operator in writing of the requirements of R315-8 and R315-3. An owner's or operator's failure to notify the new owner or operator of the requirements of R315-8 in no way relieves the new owner or operator of his obligation to comply with all applicable requirements.
2.4 GENERAL WASTE ANALYSIS
The requirements as found in 40 CFR 264.13, 1996 ed., are adopted and incorporated by reference.
2.5 SECURITY
(a) A facility owner or operator shall prevent the unknowing entry, and minimize the possibility for the unauthorized entry, of persons or livestock onto the active portion of his facility, unless he can demonstrate to the Board that:
(1) Physical contact with the waste structures, or equipment within the active portion of the facility will not injure unknowing or unauthorized persons or livestock which may enter the active portion of a facility; and
(2) Disturbance of the waste or equipment, by the unknowing or unauthorized entry of persons or livestock onto the active portion of a facility, will not cause a violation of the requirements of R315-8-2.5.
An owner or operator who wishes to make the demonstration referred to above shall do so with the part B permit application.
(b) Unless the owner or operator has made a successful demonstration under R315-8-2.5(a)(1) and (a)(2), a facility shall have:
(1) A 24-hour surveillance system, e.g., television monitoring or surveillance by guards or facility personnel, which continuously monitors and controls entry onto the active portion of the facility; or
(2)(i) An artificial or natural barrier, e.g., a fence in good repair or a fence combined with a cliff, which completely surrounds the active portion of the facility; and
(ii) A means to control entry at all times, through gates or other entrances to the active portion of the facility, e.g., an attendant, television monitors, locked entrance, or controlled roadway access to the facility. The requirements of R315-8-2.5(b) are satisfied if the facility or plant within which the active portion is located itself has a surveillance system, or a barrier and a means to control entry, which complies with the requirements of R315-8- 2.5(b)(1) or (2).
(c) Unless the owner or operator has made a successful demonstration under R315-8-2.5(a)(1) and (a)(2), a sign with the legend, "Danger - Unauthorized Personnel Keep Out", shall be posted at each entrance to the active portion of a facility, and at other locations, in sufficient numbers to be seen from any approach to the active portion. The legend shall be written in English and in any other language predominant in the area surrounding the facility and shall be legible from a distance of at least 25 feet. Existing signs with a legend other than "Danger - Unauthorized Personnel Keep Out" may be used if the legend on the sign indicates that only authorized personnel are allowed to enter the active portion, and that entry onto the active portion is potentially dangerous. Owners or operators are encouraged to also describe in the sign the type of hazard, e.g., hazardous waste, flammable wastes, etc. contained within the active portion of the facility. See R315-8-7, which incorporates by reference 40 CFR 264.110 - 264.120, for discussion of security requirements during the post-closure care period.
2.6 GENERAL INSPECTION REQUIREMENTS
(a) Facility owners or operators shall inspect their facilities for malfunctions and deterioration, operator errors, and discharges, which may be causing or may lead to release of hazardous waste constituents to the environment or pose a threat to human health. These inspections shall be conducted frequently enough to identify problems in time to take corrective action before they harm human health or the environment.
(b)(1) Facility owners or operators shall develop and follow a written schedule for inspecting monitoring equipment, safety and emergency equipment, security devices, and operating and structural equipment, such as dikes and sump pumps, that are important to preventing, detecting, or responding to environmental or human health hazards.
(2) The schedule shall be kept at the facility.
(3) The schedule shall identify the types of problems, e.g., malfunctions or deterioration, which are to be looked for during the inspection, for example, inoperative sump pump, leaking fitting, eroding dike, etc.
(4) The frequency of the inspection may vary for the items on the schedule. However, the frequency should be based on the rate of deterioration of the equipment and the probability of an environmental or human health incident if the deterioration, malfunction, or any operator error goes undetected between inspections. Areas subject to spills, such as loading and unloading areas, shall be inspected daily when they are in use. At a minimum, the inspection schedule shall include the items and frequencies called for in R315-8-9.5, R315-8-10, which incorporates by reference 40 CFR 264.190 - 264.199, R315-8-11.3, R315-8-12.3, R315-8-13.6, R315-8-14.3, R315-8-15.7, R315-8-16, which incorporates by reference 40 CFR 264.600 - 264.603, R315-8-17, which incorporates by reference 40 CFR 264.1030 - 264.1036, R315-8-18, which incorporates by reference 40 CFR 264.1050 - 264.1065, and R315-8-22, which incorporates by reference 40 CFR 264.1083 through 264.1089.
(c) The owner or operator shall make any repairs, or take other remedial action, on a time schedule which ensures that any deterioration or malfunction discovered does not lead to an environmental or human health hazard. Where a hazard is imminent or has already occurred, remedial action shall be taken immediately.
(d) The owner or operator shall keep records of inspections in an inspection log or summary. These records shall be retained for at least three years. At a minimum, these records shall include the date and time of the inspection, the name of the inspector, a notation of the observations made, and the date and nature of any repairs made or remedial actions taken.
2.7 PERSONNEL TRAINING
(a)(1) Facility personnel shall successfully complete a program of classroom instruction or on-the- job training that teaches them to perform their duties in a way that ensures the facility's compliance with the requirements of this section and that includes all the elements described in the document required under R315-8-2.7(d)(3).
(2) This program shall be directed by a person trained in hazardous waste management procedures, and shall include instruction which teaches facility personnel hazardous waste management procedures, including contingency plan implementation relevant to the position in which they are employed.
(3) At a minimum, the training program shall be designed to ensure that facility personnel are able to respond effectively to emergencies by familiarizing them with emergency procedures, emergency equipment, and emergency systems, including, but not necessarily limited to, the following, where applicable:
(i) Procedures for inspection, use, repair, and replacement of facility emergency and monitoring equipment;
(ii) Communications or alarm systems;
(iii) Key parameters for automatic waste feed cut-off systems;
(iv) Response to fires or explosions;
(v) Response to groundwater contamination incidents; and
(vi) Shutdown of operations.
(b) Facility personnel shall successfully complete the program required in R315-8-2.7(a) within six months after the effective date of these rules or six months after the date of employment or assignment to a facility, or to a new position at a facility, whichever is later. Employees hired after the effective date of these rules shall not work in unsupervised positions until they have completed the training requirements of R315-8-2.7(a).
(c) Facility personnel shall take part in an annual review of their initial training in both contingency procedures and the hazardous waste management procedures relevant to the positions in which they are employed.
(d) Owners or operators of facilities shall maintain the following documents and records and make them available upon request:
(1) The job title for each position at the facility related to hazardous waste management, and the name of the employee filling each job;
(2) A written job description for each position listed under R315-8-2.7(d)(1). This description may be consistent in its degree of specificity with descriptions for other similar positions in the same company location or bargaining unit, but shall include the requisite skill, education, or other qualifications and duties of employees assigned to each position;
(3) A written description of the type and amount of both introductory and continuing training that will be given to each person filling a position listed under R315-8-2.7(d)(1);
(4) Records that document that the training or job experience required under R315-8-2.7(a), (b), and (c) has been given to, and completed by, facility personnel.
(e) Training records on current employees shall be maintained until closure of the facility; training records on former employees shall be retained for at least three years from the date the employee last worked at the facility. Employee training records may accompany personnel transferred within the same company.
2.8 GENERAL REQUIREMENTS FOR IGNITABLE, REACTIVE, OR INCOMPATIBLE WASTES
(a) The owner or operator shall take precautions to prevent accidental ignition or reaction of ignitable or reactive wastes. These waste shall be separated and protected from sources of ignition or reaction including but not limited to: open flames, smoking, cutting and welding, hot surfaces, frictional heat, sparks, static, electrical, or mechanical, spontaneous ignition, e.g., from heat-producing chemical reactions, and radiant heat. While ignitable or reactive waste is being handled, the owner or operator shall confine smoking and open flame to specially designated locations. "No Smoking" signs shall be conspicuously placed wherever there is a hazard from ignitable or reactive waste.
(b) Where specifically required by other sections of R315-8, the owner or operator of a facility that treats, stores or disposes ignitable or reactive waste, or mixes incompatible waste or incompatible wastes and other materials, shall take precautions to prevent reactions which:
(1) Generate extreme heat or pressure, fire or explosion, or violent reactions;
(2) Produce uncontrolled toxic mists, fumes, dusts, or gases in sufficient quantities to threaten human health or the environment;
(3) Produce uncontrolled flammable fumes or gases in sufficient quantities to pose a risk of fire or explosions;
(4) Damage the structural integrity of the device or facility;
(5) Through other like means threaten human health or the environment.
(c) When required to comply with R315-8-2.8, the owner or operator shall document that compliance. This documentation may be based on references to published scientific or engineering literature, date from trial tests, e.g., bench scale or pilot scale tests, waste analyses as specified in R315-8-2.4, which incorporates by reference 40 CFR 264.13, or the results of the treatment of similar wastes by similar treatment processes and under similar operating conditions.
2.9 LOCATION STANDARDS
(a) Seismic considerations.
(1) Portions of new facilities where treatment, storage, or disposal of hazardous waste will be conducted shall not be located within 61 meters (200 feet) of a fault which has had displacement in Holocene time. For definition of terms used in this section see R315-1. Procedures for demonstrating compliance with this standard in part B of the permit application are specified in R315-3 specifically in R315-3-2.5. Facilities which are located in political jurisdictions other than those listed in R315-50-11 are assumed to be in compliance with this requirement.
(b) Floodplains.
(1) A facility located in a 100-year floodplain shall be designed, constructed, operated and maintained to prevent washout of any hazardous waste by a 100-year flood, unless the owner or operator can demonstrate to the Executive Secretary's satisfaction that:
(i) Procedures are in effect which will cause the waste to be removed safely, before flood waters can reach the facility, to a location where the wastes will not be vulnerable to flood waters; or
(ii) For existing surface impoundments, waste piles, land treatment units, landfills, and miscellaneous units, no adverse effects on human health or the environment will result if washout occurs, considering:
(A) The volume and physical and chemical characteristics of the waste in the facility;
(B) The concentration of hazardous constituents that would potentially affect surface waters as a result of washout;
(C) The impact of such concentrations on the current or potential uses of and water quality standards established for the affected surface waters; and
(D) The impact of hazardous constituents on the sediments of affected surface waters or the soils of the 100-year floodplain that could result from washout. The location where wastes are moved shall be a facility which is either permitted by EPA or has a permit in accordance with R315-3.
(2) As used in R315-8-2.9(b)(1):
(i) "100-year floodplain" means any land area which is subject to a one percent or greater chance of flooding in any given year from any source;
(ii) "Washout" means the movement of hazardous waste from the active portion of the facility as a result of flooding;
(iii) "100-year flood" means a flood that has a one percent chance of being equalled or exceeded in any given year.
(c) Salt dome formations, salt bed formations, underground mines and caves.
The placement of any non-containerized or bulk liquid hazardous wastes in any salt dome formation, salt bed formation, underground mine or cave is prohibited, except for the Department of Energy Waste Isolation Pilot Project in New Mexico.
2.10 CONSTRUCTION QUALITY ASSURANCE PROGRAM
(a) CQA program. (1) A construction quality assurance (CQA) program is required for all surface impoundment, waste pile, and landfill units that are required to comply with R315-8-11.2(c) and (d), R315-8-12.2(c) and (d), and R315-8-14.2(c) and (d). The program shall ensure that the constructed unit meets or exceeds all design criteria and specifications in the permit. The program shall be developed and implemented under the direction of a CQA officer who is a registered professional engineer.
(2) The CQA program shall address the following physical components, where applicable:
(i) Foundations;
(ii) Dikes;
(iii) Low-permeability soil liners;
(iv) Geomembranes, flexible membrane liners;
(v) Leachate collection and removal systems and leak detection systems; and
(vi) Final cover systems.
(b) Written CQA plan. The owner or operator of units subject to the CQA program under R315-8-2.10(a) shall develop and implement a written CQA plan. The plan must identify steps that will be used to monitor and document the quality of materials and the condition and manner of their installation. The CQA plan shall include:
(1) Identification of applicable units, and a description of how they will be constructed.
(2) Identification of key personnel in the development and implementation of the CQA plan, and CQA officer qualifications.
(3) A description of inspection and sampling activities for all unit components identified in R315-8- 2.10(a)(2), including observations and tests that will be used before, during, and after construction to ensure that the construction materials and the installed unit components meet the design specifications. The description shall cover: Sampling size and locations; frequency of testing; data evaluation procedures; acceptance and rejection criteria for construction materials; plans for implementing corrective measures; and data or other information to be recorded and retained in the operating record under R315-8-5.3.
(c) Contents of program. (1) The CQA program shall include observations, inspections, tests, and measurements sufficient to ensure:
(i) Structural stability and integrity of all components of the unit identified in R315-8- 2.10(a)(2);
(ii) Proper construction of all components of the liners, leachate collection and removal system, leak detection system, and final cover system, according to permit specifications and good engineering practices, and proper installation of all components, e.g., pipes, according to design specifications;
(iii) Conformity of all materials used with design and other material specifications under R315-8- 11.2, R315-8-12.2, and R315-8-14.2.
(2) The CQA program shall include test fills for compacted soil liners, using the same compaction methods as in the full scale unit, to ensure that the liners are constructed to meet the hydraulic conductivity requirements of R315-8-11.2(c)(1)(i)(B), R315-8-12.2(c)(1)(i)(B), and R315-8-14.2(c)(1)(i)(B) in the field. Compliance with the hydraulic conductivity requirements shall be verified by using in-situ testing on the constructed test fill. The Executive Secretary may accept an alternative demonstration, in lieu of a test fill, where data are sufficient to show that a constructed soil liner will meet the hydraulic conductivity requirements of R315-8-11.2(c)(1)(i)(B), R315-8-12.2(c)(1)(i)(B), and R315-8- 14.2(c)(1)(i)(B) in the field.
(d) Certification. Waste shall not be received in a unit subject to R315-8-2.10 until the owner or operator has submitted to the Executive Secretary by certified mail or hand delivery a certification signed by the CQA officer that the approved CQA plan has been successfully carried out and that the unit meets the requirements of R315-8- 11.2(c) or (d), R315-8-12.2(c) or (d), or R315-8-14.2(c) or (d); and the procedure in R315-3-3.1(l)(2)(ii) has been completed. Documentation supporting the CQA officer's certification shall be furnished to the Executive Secretary upon request.
3.1 APPLICABILITY
The regulations in this section apply to the owners or operators of all hazardous waste management facilities, except as provided otherwise in R315-8-1.
3.2 DESIGN AND OPERATION OF FACILITY
Facilities shall be designed, constructed, maintained, and operated to minimize the possibility of a fire, explosion, or any unplanned sudden or non-sudden discharge of hazardous waste or hazardous waste constituents to air, soil, groundwater, or surface water which could threaten the environment or human health.
3.3 REQUIRED EQUIPMENT
All facilities shall be equipped with the following, unless it can be demonstrated to the Board that there are no hazards at the facility which could require a particular kind of equipment specified below:
(a) An internal communications or alarm system capable of providing immediate emergency instruction, voice or signal, to facility employees;
(b) A device capable of summoning external emergency assistance from local law enforcement agencies, fire departments, or State or local emergency response teams, such as a telephone, immediately available at the scene of operations, or a hand-held two-way radio;
(c) Portable fire extinguishers, fire control equipment, including special extinguishing equipment, such as that using foam, inert gas, or dry chemicals, discharge control equipment, and decontamination equipment; and
(d) Water at adequate volume and pressure to supply water hose streams, or foam producing equipment, or automatic sprinklers, or water spray systems. This demonstration shall be made with the part B permit application.
3.4 TESTING AND MAINTENANCE OF EQUIPMENT
All facility communications or alarm systems, fire protection equipment, safety equipment, discharge control equipment, and decontamination equipment, where required, shall be tested and maintained as necessary to assure its proper operation in time of emergency.
3.5 ACCESS TO COMMUNICATIONS OR ALARM SYSTEM
(a) Whenever hazardous waste is being poured, mixed, spread, or otherwise handled, all employees involved in the operation shall have immediate access to an internal alarm or emergency communication device, either directly or through visual or voice contact with another employee, unless the Board has ruled that this type of a device is not required under R315-8-3.3.
(b) If there is just one employee on the premises while the facility is operating, he shall have immediate access to a device capable of summoning external emergency assistance, such as a telephone, immediately available at the scene of operation, or a hand-held two-way radio, unless the Board has ruled that this type of a device is not required under R315-8-3.3.
3.6 REQUIRED AISLE SPACE
The facility owner or operator shall maintain aisle space to allow the unobstructed movement of personnel, fire protection equipment, discharge control equipment, and decontamination equipment to any area of facility operation in an emergency, unless it can be demonstrated to the Board that aisle space is not needed for any of these purposes. This demonstration shall be made with the part B permit application.
3.7 ARRANGEMENTS WITH LOCAL AUTHORITIES
(a) The owner or operator shall attempt to make the following arrangements, as appropriate for the type of waste handled at his facility and the potential need for the services of these organizations:
(1) Arrangements to familiarize law enforcement agencies, fire departments, and emergency response teams with the layout of the facility, properties of hazardous waste handled at the facility and associated hazards, places where facility personnel would normally be working, entrances to and roads inside the facility, and possible evacuation routes;
(2) Where more than one law enforcement agency and fire department might respond to an emergency, agreements designating primary emergency authority to a specific law enforcement agency and a specific fire department, and agreements with any others to provide support to the primary emergency authority;
(3) Agreements with State emergency response teams, emergency response contractors, and equipment suppliers; and
(4) Arrangements to familiarize local hospitals with the properties of hazardous waste handled at the facility and the types of injuries or illnesses which could result from fires, explosions, or releases at the facility.
(b) Where State or local authorities decline to enter into these arrangements, the owner or operator shall document the refusal in the operating record.
4.1 APPLICABILITY
The regulations in this section apply to the owners and operators of all hazardous waste management facilities, except as provided otherwise in R315-8-1(e).
4.2 PURPOSE AND IMPLEMENTATION OF CONTINGENCY PLAN
(a) Each owner or operator shall have a contingency plan for his facility. The contingency plan shall be designed to minimize hazards to human health or the environment from fires, explosions, or any unplanned sudden or non-sudden discharge of hazardous waste or hazardous waste constituents to air, soil, groundwater, or surface water.
(b) The provisions of the plan shall be carried out immediately whenever there is a fire, explosion, or discharge of hazardous waste or hazardous waste constituents which could threaten the environment or human health.
4.3 CONTENT OF CONTINGENCY PLAN
(a) The plan shall describe the actions facility personnel shall take to comply with R315-8-4.2 and R315-8-4.7 in response to fires, explosions or any unplanned sudden or non-sudden discharge of hazardous waste or hazardous waste constituents to air, soil, or surface water at the facility. If a facility owner or operator already has prepared a Spill Prevention, Control and Countermeasures (SPCC) Plan in accordance with 40 CFR 112, or some other emergency or contingency plan, he need only amend that plan to incorporate hazardous waste management provisions sufficient to comply with the requirements of this section.
(b) The plan shall describe arrangements agreed to by local law enforcement agencies, fire departments, hospitals, contractors, and State and local emergency response teams to coordinate emergency services pursuant to R315-8-3.7.
(c) The plan shall list names, addresses and phone numbers, office and home, of all persons qualified to act as facility emergency coordinator, see R315-8-4.6, and this list shall be kept up-to-date. Where more than one person is listed, one shall be named as primary emergency coordinator and others shall be listed in the order in which they assume responsibility as alternates. For new facilities, this information shall be supplied to the Board before operations begin rather than at the time of submission of the plan.
(d) The plan shall include a list of all emergency equipment at the facility, such as fire extinguishing systems, discharge control equipment, communications and alarm systems, internal and external, and decontamination equipment, where this equipment is required. This list shall be kept up-to-date. In addition, the plan shall include the location and a physical description of each item on the list, and a brief outline of its capabilities.
(e) The plan shall include an evacuation plan for facility personnel where there is a possibility that evacuation could be necessary. This plan shall describe signal(s) to be used to begin evacuation, evacuation routes, and alternate evacuation routes, in cases where the primary routes could be blocked by discharges of hazardous waste or fires.
4.4 COPIES OF A CONTINGENCY PLAN
A copy of the contingency plan and all revisions to the plan shall be:
(a) Maintained at the facility;
(b) Made available upon request; and
(c) Submitted to all local law enforcement agencies, fire departments, hospitals, and State and local emergency response teams that may be called upon to provide emergency services.
The contingency plan shall be submitted to the Board with part B of the permit application under R315- 3 and after modification or approval will become a condition of any permit issued.
4.5 AMENDMENT OF CONTINGENCY PLAN
The contingency plan shall be reviewed, and immediately amended, if necessary, under any of the following circumstances:
(a) Revisions to the facility permit;
(b) Failure of the plan in an emergency;
(c) Changes in the facility design, construction, operation, maintenance, or other circumstances that materially increase the potential for fires, explosions, or discharges of hazardous waste or hazardous waste constituents, or changes the response necessary in an emergency;
(d) Changes in the list of emergency coordinators; or
(e) Changes in the list of emergency equipment.
4.6 EMERGENCY COORDINATOR
At all times there shall be at least one employee either present on the facility premises or on call, i.e., available to respond to an emergency by reaching the facility within a short time period, with the responsibility for coordinating all emergency response measures. This facility emergency coordinator shall be thoroughly familiar with all aspects of the facility's contingency plan, all operations and activities at the facility, the location and characteristics of waste handled, the location of manifests and all other records within the facility, and the facility layout. In addition, this person shall have the authority to commit the resources needed to carry out the contingency plan. The emergency coordinator's responsibilities are more fully spelled out in R315-8-4.7. Applicable responsibilities for the emergency coordinator vary, depending on factors such as type and variety of waste(s) handled by the facility, and type and complexity of the facility.
4.7 EMERGENCY PROCEDURES
(a) Whenever there is an imminent or actual emergency situation, the facility's emergency coordinator, or his designee when the emergency coordinator is on call, shall immediately:
(1) Activate internal facility alarms or communication systems, where applicable, to notify all facility personnel; and
(2) Notify appropriate State or local agencies with designated response roles whenever their assistance is needed.
(b) In the event of a discharge, fire, or explosion, the facility's emergency coordinator shall immediately identify the character, exact source, amount, and areal extent of any discharged materials. He may do this by observation or review of facility records or manifests, and, if necessary, by chemical analysis.
(c) Concurrently, the facility's emergency coordinator shall assess possible hazards to the environment or human health that may result from the discharge, fire, or explosion. This assessment shall consider both direct and indirect effects of the discharge, fire, or explosion, e.g., the effects of any toxic, irritating, or asphyxiating gases that are generated, or the effects of any hazardous surface water run-off or hazardous groundwater infiltration from water or chemical agents used to control fire and heat-induced explosions.
(d) The facility's emergency coordinator shall immediately report his assessment that the facility has had a discharge, fire, or explosion which could threaten human health, or the environment, outside the facility, as follows:
(1) If his assessment indicates that evacuation of local areas may be advisable, he shall immediately notify appropriate local authorities. He shall be available to assist appropriate officials in making the decision whether local areas should be evacuated; and
(2) He shall immediately notify both the Utah State Department of Environmental Quality as specified in R315-9 and the government official designated as the on-scene coordinator for that geographical area, in the applicable regional contingency plan, or the National Response Center (800/424-8802). The report shall include:
(i) Name and telephone number of reporter;
(ii) Name and address of facility;
(iii) Time and type of incident, e.g., discharge, fire;
(iv) Name and quantity of material(s) involved, to the extent available;
(v) The extent of injuries, if any; and
(vi) The possible hazards to human health, or the environment, outside the facility.
(e) During an emergency, the facility's emergency coordinator shall take all reasonable measures necessary to ensure that fires, explosions, and discharges do not occur, recur, or spread to other hazardous waste at the facility. These measures shall include, where applicable, stopping processes and operations, collecting and containing discharged waste, and removing or isolating containers.
(f) If the facility stops operations in response to a discharge, fire, or explosion, the facility's emergency coordinator shall monitor for leaks, pressure buildup, gas generation, or ruptures in valves, pipes, or other equipment, wherever this is appropriate.
(g) Immediately after an emergency, the emergency coordinator shall provide for treating, storing, or disposing of recovered waste, contaminated soil or surface water, or any other material that results from a discharge, fire, or explosion at the facility. The recovered material shall be handled and managed as a hazardous waste unless it is analyzed and determined not to be, using the procedures specified in R315-2.
(h) The facility's emergency coordinator shall ensure that, in the affected area(s) of the facility:
(1) No waste that may be incompatible with the released material is treated, stored, or disposed of until cleanup procedures are completed; and
(2) All emergency equipment listed in the contingency plan is cleaned and fit for its intended use before operations are resumed.
(i) The facility owner or operator shall notify the Executive Secretary and other appropriate State and local authorities, that the facility is in compliance with R315-8-4.7(h) before operations are resumed in the affected area(s) of the facility.
(j) The facility owner or operator shall record in the operating record the time, date, and nature of any incident that requires implementing the contingency plan. Within 15 days after the incident, he shall submit a written report on the emergency to the Executive Secretary. The report shall include:
(1) Name, address, and telephone number of the owner or operator;
(2) Name, address, and telephone number of the facility;
(3) Date, time, and type of incident, e.g., fire, discharge;
(4) Name and quantity of material(s) involved;
(5) The extent of injuries, if any;
(6) An assessment of actual or potential hazards to the environment or human health, where this is applicable; and
(7) Estimated quantity and disposition of recovered material that resulted from the incident.
5.1 APPLICABILITY
(a) The rules in R315-8-5 apply to owners and operators of both on-site and off-site facilities, except as provided otherwise in R315-8-1. R315-8-5.2, R315-8-5.4, and R315-8-5.7 do not apply to owners and operators of on-site facilities that do not receive hazardous waste from off-site sources, nor to owners and operators of off-site facilities with respect to waste military munitions exempted from manifest requirements under 40 CFR 266.203(a). R315-8- 5.3, which incorporates by reference 40 CFR 264.73(b) only applies to permittees who treat, store, or dispose of hazardous wastes on-site where such wastes were generated.
(b) The revised Manifest form and procedures in R315-1-1, which incorporates by reference 40 CFR 260.10, R315-2-7, R315-8-5.1, R315-8-5.2, R315-8-5.4, and R315-8-5.7, contained in R315-1 to R315-8, edition revised as of September 15, 2004, shall be applicable until September 5, 2006.
5.2 USE OF MANIFEST SYSTEM
(a)(1) If a facility receives hazardous waste accompanied by a manifest, the owner or operator, or his agent, shall sign and date the manifes as indicated in R315-8-5.2(a)(2) to certify that the hazardous waste covered by the manifest was received, that the hazardous waste was received except as noted in the discrepancy space of the manifes, or that the hazardous waste was rejected as noted in the manifest discrepancy space.
(2) If a facility receives a hazardous waste shipment accompanied by a manifest, the owner, operator or his agent shall:
(i) Sign and date, by hand, each copy of the manifest;
(ii) Note any discrepancies in the manifest, as defined in R315-8-5.4(a), on each copy of the manifest;
(iii) Immediately give the transporter at least one copy of the signed manifest;
(iv) Within 30 days of the delivery, send a copy of the manifest to the generator; and
(v) Retain at the facility a copy of each manifest for at least three years from the date of delivery.
(3) If a faciity receives hazardous waste imported from a foreign source, the receiving facility shall mail a cop of the manifest to the following addresses within 30 days of delivery: International Compliance Assurance Division, OFA/OECA (2254A), U.S. Environmental Protection Agency, Ariel Rios Building, 1200 Pennsylvania Avenue, NW., Washington DC 20460 and Utah Division of Solid and Hazardous Waste, P O Box 144880, Salt Lake City, Utah 84114-4880.
(b) If a facility receives, from a rail or water (bulk shipment) transporter, hazardous waste which is accompanied by a shipping paper containing all the information required on the manifest (excluding the EPA identification numbers, generator's certification, and signatures), the owner or operator, or his agent, shall:
(1) Sign and date each copy of the manifest or shipping paper (if the manifest has not been received) to certify that the hazardous waste covered by the manifest or shipping paper was received;
(2) Note any significant discrepancies, as defined in R315-8-5.4(a), in the manifest or shipping paper (if the manifest has not been received) on each copy of the manifest or shipping paper.
Comment: The Agency does not intend that the owner or operator of a facility whose procedures under R315-8-2.4, which incorporates by reference 40 CFR 264.13(c), include waste analysis shall perform that analysis before signing the shipping paper and giving it to the transporter. R315-8-5.4(b), however, requires reporting an unreconciled discrepancy discovered during later analysis.
(3) Immediately give the rail or water (bulk shipment) transporter at least one copy of the manifest or shipping paper (if the manifest has not been received);
(4) Within 30 days after the delivery, send a copy of the signed and dated manifest or a signed and dated copy of the shipping papaer (if the manifest has not been received within 30 days after delivery) to the generator; and
Comment: R315-5-2.23(c) requires the generator to send three copies of the manifest to the facility when hazardous waste is sent by rail or water (bulk shipment).
(5) Retain at the facility a copy of the manifest and shipping paper (if signed in lieu of the manifest at the time of delivery) for at least three years from the date of delivery.
(c) Whenever a shipment of hazardous waste is initiated from a facility, the owner or operator of that facility shall comply with the requirements of R315-5.
Comment: The provisions of R315-5-3.34, which incorporates by reference 40 CFR 262.34, are applicable to the on-site accumulation of hazardous wastes by generators. Therefore, the provisions of R315-5-3.34, which incorporates by reference 40 CFR 262.34, only apply to owners or operators who are shipping hazardous waste which they generated at that facility.
(d) Within three working days of the receipt of a shipment subject to R315 -5-8, which incorporates by reference 40 CFR 262, subpart H, the owner or operator of the facility shall provide a copy of the tracking document bearing all required signatures to the notifier, to the Office of Enforcement and Compliance Assurance, Office of Compliance, Enforcement Planning, Targeting and Data Division (2222A), Environmental Protection Agency, 401 M St., SW., Washington, DC 20460, and to competent authorities of all other concerned countries. The original copy of the tracking document shall be maintained at the facility for at least three years from the date of signature.
(e) A facility shall determine whether the consignment state for a shipment regulates any additional wastes (beyond those regulated Federally) as hazardous wastes under its state hazardous waste program. Facilities shall also determine whether the consignment state or generator state requires the facility to submit any copies of the manifest to these states.
5.3 OPERATING RECORD
The requirements as found in 40 CFR 264.73, 2000 ed., are adopted and incorporated by reference.
5.4 MANIFEST DISCREPANCIES
(a) Manifest discrepancies are:
(1) Significant differences (as defined by R315-8-5.4(b)) between the quantity or type of hazardous waste designated on the manifest or shipping paper, and the quantity and type of hazardous waste a facility actually receives;
(2) Rejected wastes, which may be a full or partial shipment of hazardous waste that the treatment, storage, or disposal facility cannot accept; or
(3) Container residues, which are residues that exceed the quantity limits for "empty" containers set forth in R315-2-7(b).
(b) Significant discrepancies in quantity are: for batch waste, any variation in piece count, such as a discrepancy of one drum in a truckload; for bulk waste, variations greater than 10 percent in weight. Significant discrepancies in type are obvious differences which can be discovered by inspection or waste analysis, such as waste solvent substituted for waste acid, or toxic constituents not reported on the manifest or shipping paper.
(c) Upon discovering a significant discrepancy, the owner or operator shall attempt to reconcile the discrepancy with the waste generator or transporter, e.g., with telephone conversations. If the discrepancy is not resolved within 15 days after receiving the waste, the owner or operator shall immediately submit to the Executive Secretary a letter describing the discrepancy and attempts to reconcile it, and a copy of the manifest or shipping paper at issue.
(d)(1) Upon rejecting waste or identifying a container residue that exceeds the quantity limits for "empty" containers set forth in R315-2-7(b), the facility shall consult with the generator prior to forwarding the waste to another facility that can manage the waste. If it is impossible to locate an alternative facility that can receive the waste, the facility may return the rejected waste or residue to the generator. The facility shall send the waste to the alternative facility or to the generator within 60 days of the rejection or the container residue identification.
(2) While the facility is making arrangements for forwarding rejected wastes or residues to another facility under R315-8-5.4, it must ensure that either the delivering transporter retains custody of the waste, pending delivery of the waste to the first transporter designated on the manifest prepared under R315-8-5.4(e) or (f).
(e) Except as provided in R315-8-5.4(e)(7), for full or partial load rejections and residues that are to be sent off-site to an alternate facility, the facility is required to prepare a new manifest in accordance with R315-5-2.20(a) and the following instructions:
(1) Write the generator's U.S. EPA ID number in Item 1 of the new manifest. Write the generator's name and mailing address in Item 5 of the new manifest. If the mailing address is different from the generator's site address, then write the generator's site address in the designated space for Item 5.
(2) Write the name of the alternate designated facility and the facility's U.S. EPA ID number in the designated facility block (Item 8) of the new manifest.
(3) Copy the manifest tracking number found in Item 4 of the old manifest to the Special Handling and Additional Information Block of the new manifest, and indicate that the shipment is a residue or rejected waste from the previous shipment.
(4) Copy the manifest tracking number found in Item 4 of the new manifest to the manifest reference number line in the Discrepancy Block of the old manifest (Item 18a) of R315.
(5) Write the DOT description for the rejected load or the residue in Item 9 (U.S. DOT Description) of the new manifest and write the container types, quantity, and volume(s) of waste.
(6) Sign the Generator's/Offeror's Certification to certify, as the offeror of the shipment, that the waste has been properly packaged, marked, and labeled and is in proper condition for transportation.
(7) For full load rejections that are made while the transporter remains present at the facility, the facility may forward the rejected shipment to the alternate facility by completing Item 18b of the original manifest and supplying the information on the next destination facility in the Alternate Facility space. The facility shall retain a copy of this manifest for its records, and then give the remaining copies of the manifest to the transporter to accompany the shipment. If the original manifest is not used, then the facility shall use a new manifest and comply with R315-8- 5.4(e)(1), (2), (3), (4), (5), and (6).
(f) Except as provided in R315-8-5.4(f)(7), for rejected wastes and residues that shall be sent back to the generator, the facility is required to prepare a new manifest in accordance with R315-5-2.20(a) and the following instructions:
(1) Write the facility's U.S. EPA ID number in Item 1 of the new manifest. Write the generator's name and mailing address in Item 5 of the new manifest. If the mailing address is different from the generator's site address, then write the generator's site address in the designated space for Item 5.
(2) Write the name of the initial generator and the generator's U.S. EPA ID number in the designated facility block (Item 8) of the new manifest.
(3) Copy the manifest tracking number found in Item 4 of the old manifest to the Special Handling and Additional Information Block of the new manifest, and indicate that the shipment is a residue or rejected waste from the previous shipment.
(4) Copy the manifest tracking number found in Item 4 of the new manifest to the manifest reference number line in the Discrepancy Block of the old manifest (Item 18a).
(5) Write the DOT description for the rejected load or the residue in Item 9 (U.S. DOT Description) of the new manifest and write the container types, quantity, and volume(s) of waste.
(6) Sign the Generator's/Offeror's Certification to certify, as offeror of the shipment, that the waste has been properly packaged, marked, and labeled and is in proper condition for transportation.
(7) For full load rejections that are made while the transporter remains at the facility, the facility may return the shipment to the generator with the original manifest by completing Item 18a and 18b of the manifest and supplying the generator's information in the Alternate Facility space. The facility shall retain a copy for its records and then give the remaining copies of the manifest to the transporter to accompany the shipment. If the original manifest is not used, then the facility shall use a new manifest and comply with R315-8-5.4(f)(1), (2), (3), (4), (5), and (6).
(g) If a facility rejects a waste or identifies a container residue that exceeds the quantity limits for "empty" containers set for in R315-2-7(b) after it has signed, date, and returned a copy of the manifest to the delivering transporter or to the generator, the facility shall amend its copy of the manifest to indicate the rejected wastes or residues in the discrepancy space of the amended manifest. The facility shall also copy the manifest tracking number from Item 4 of the new manifest to the Discrepancy space of the amended manifest, and shall re-sign and date the manifest to certify to the information as amended. The facility shall retain the amended manifest for at least three years from the date of amendment, and shall within30 days, send a copy of the amended manifest to the transporter and generator that received copies prior to their being amended.
5.5 AVAILABILITY, RETENTION, AND DISPOSITION OF RECORDS
(a) Records of waste disposal locations and quantities required to be maintained under R315-8-5.3, which incorporates by reference 40 CFR 264.73(b)(2) shall be submitted to the Board and local land authority upon closure of the facility.
(b) The retention period for all records required under this section is extended automatically during the course of any unresolved enforcement action regarding the facility or as requested by the Executive Secretary.
(c) All records, including plans, required under R315-8 shall be furnished upon request, and made available at all reasonable times for inspection.
5.6 BIENNIAL REPORT
Owners or operators of facilities that treat, store, or dispose of hazardous waste shall prepare and submit a single copy of an biennial report to the Board by March 1 of each even numbered year. The biennial report shall be submitted on EPA form 8700-13B. The biennial report shall cover facility activities during the previous calendar year and shall include the following information:
(a) The EPA identification number, name, and address of the facility;
(b) The calendar year covered by the report;
(c) For off-site facilities, the EPA identification number of each hazardous waste generator from which a hazardous waste was received during the year; for imported shipments, the name and address of the foreign generator shall be given in the report;
(d) A description and the quantity of each hazardous waste received by the facility during the year. For off-site facilities, this information shall be listed by EPA identification number of each generator;
(e) The method(s) of treatment, storage, or disposal for each hazardous waste; and
(f) The most recent closure cost estimate under R315-8-8, which incorporates by reference 40 CFR 264. 140 - 264.151, and for disposal facilities, the most recent post-closure cost estimate under R315-8-8, which incorporates by reference 40 CFR 264.140 - 264.151; and
(g) For generators who treat, store, or dispose of hazardous waste on-site, a description of the efforts undertaken during the year to reduce the volume and toxicity of waste generated;
(h) For generators who treat, store, or dispose of hazardous waste on-site, a description of the changes in volume and toxicity of waste actually achieved during the year in comparison to previous years to the extent the information is available for the years prior to 1984;
(i) The certification signed by the owner or operator of the facility or his authorized representative.
5.7 UNMANIFESTED WASTE REPORT
(a) If a facility accepts for treatment, storage, or disposal any hazardous waste from an off-site source without an accompanying manifest, or without an accompanying shipping paper as described in R315-6-2.20(e)(2), and if the waste is not excluded from the manifest requirement of R315, then the owner or operator shall prepare and submit a letter to the Executive Secretary within 15 days of the receipt of the waste. The unmanifested waste report shall include the following information:
(1) The EPA identification number, name, and address of the facility;
(2) The date of receipt of the waste;
(3) The EPA identification number, name and address of the generator and the transporter, if available;
(4) A description and the quantity of each unmanifested hazardous waste the facility received;
(5) The method of treatment, storage, or disposal for each hazardous waste;
(6) The certification signed by the owner or operator of the facility or his authorized representative; and
(7) A brief explanation of why the waste was unmanifested, if known.
5.8 ADDITIONAL REPORTS
In addition to the biennial and unmanifested waste reporting requirements described in R315-8-5.6 and R315-8, a facility owner operator shall also report the following to the Board:
(a) Discharges, fires, and explosions as specified in R315-8-4.7(j);
(b) Upon its request, all information as the Board may deem necessary to determine compliance with the requirements of R315-8;
(c) Facility closure as specified in R315-8-7, which incorporates by reference 40 CFR 264.110 - 264.120; and
(d) As otherwise required in R315-8-6, R315-8-11, R315-8-12, R315-8-13, R315-8-14, R315-8-17, which incorporates by reference 40 CFR 264-1030 - 264.1036, R315-8-18, which incorporates by reference 40 CFR 264.1050 - 264.1065, and R315-8-22, which incorporates by reference 40 CFR 264.1080 - 264.1090.
6.1 APPLICABILITY
(a)(1) Except as provided in R315-8-6.1(b), R315-8-6 applies to owners or operators of facilities that treat, store or dispose of hazardous waste. The owner or operator shall satisfy the requirements identified in R315-8- 6.1(a)(2) for all wastes, or constituents thereof, contained in solid waste management units at the facility, regardless of the time at which waste was placed in the units.
(2) All solid waste management units shall comply with the requirements in R315-8-6.12. A surface impoundment, waste pile, and land treatment unit or landfill that receives hazardous waste after July 26, 1982, hereinafter referred to as a "regulated unit", shall comply with the requirements of R315-8-6.2 through R315-8-6.11 in lieu of R315-8- 6.12 for purposes of detecting, characterizing and responding to releases to the uppermost aquifer. The financial responsibility requirements of R315-8-6.12 apply to regulated units.
(3) Groundwater monitoring shall be required at non-land disposal facilities as determined to be necessary and appropriate by the Executive Secretary.
(b) The owner or operator's regulated unit or units are not subject to regulation for releases into the uppermost aquifer under R315-8-6 if:
(1) The owner or operator is exempted under R315-8-1(e) or
(2) He operates a unit which the Board finds:
(i) Is an engineered structure.
(ii) Does not receive or contain liquid waste or waste containing free liquid.
(iii) Is designed and operated to exclude liquid, precipitation, and other run-on and run-off.
(iv) Has both inner and outer layers of containment enclosing the waste.
(v) Has a leak detection system built into each containment layer.
(vi) The owner or operator will provide continuing operation and maintenance of these leak detection systems during the active life of the unit and the closure and post-closure care periods, and
(vii) To a reasonable degree of certainty, will not allow hazardous constituents to migrate beyond the outer containment layer prior to the end of the post-closure care period.
(3) The Board finds pursuant to R315-8-13.11(d) that the treatment zone of a land treatment unit that qualifies as a regulated unit does not contain levels of hazardous constituents that are above background levels of those constituents by an amount that is statistically significant, and if an unsaturated zone monitoring program meeting the requirements of R315-8-13.9 has not shown a statistically significant increase in hazardous constituents below the treatment zone during the operating life of the unit. An exemption under this paragraph can only relieve an owner or operator of responsibility to meet the requirements of this subpart during the post-closure care period; or
(4) The Board finds that there is no potential for migration of liquid from a regulated unit to the uppermost aquifer during the active life of the regulated unit, including the closure period and the post-closure care period specified under R315-8-7, which incorporates by reference 40 CFR 264.110 - 264.120. This demonstration shall be certified by a qualified geologist or geotechnical engineer. In order to provide an adequate margin of safety in the prediction of potential migration of liquid, the owner or operator shall base any predictions made under this paragraph on assumptions that maximize the rate of liquid migration.
(5) He designs and operates a waste pile in compliance with R315-8-12.1(c).
(c) The regulations under this section apply during the active life of the regulated unit, including the closure period. After closure of the regulated unit, the regulations in this section:
(1) Do not apply if the waste, waste residues, contaminated containment system components, and contaminated subsoils are removed or decontaminated at closure;
(2) Apply during the post-closure care period under R315-8-7, which incorporates by reference 40 CFR 264.110 - 264-120, if the owner or operator is conducting a detection monitoring program under R315-8-6.9;
(3) Apply during the compliance period under R315-8-6.7 the owner is conducting a compliance monitoring program under R315-8-6.10 or a corrective action program under R315-8-6.11.
(d) Requirements in this section may apply to miscellaneous units when necessary to comply with R315- 8-24, which incorporates by reference 40 CFR 264.601 - 264.603.
(e) The regulations of R315-8-6 apply to all owners and operators subject to the requirements of R315-3-1.1(e)(7), when the Executive Secretary issues either a post-closure permit or an enforceable document, as defined in R315-3-1.1(e)(7), at the facility. When the Executive Secretary issues an enforceable document, references in R315-8-6 to "in the permit'' mean "in the enforceable document.''
(f) The Executive Secretary may replace all or part of the requirements of R315-8-6.2 through R315-8- 6.11 applying to a regulated unit with alternative requirements for groundwater monitoring and corrective action for releases to groundwater set out in the permit, or in an enforceable document, as defined in R315-3-1.1(e)(7) where the Executive Secretary determines that:
(1) The regulated unit is situated among solid waste management units, or areas of concern, a release has occurred, and both the regulated unit and one or more solid waste management unit(s), or areas of concern, are likely to have contributed to the release; and
(2) It is not necessary to apply the groundwater monitoring and corrective action requirements of R315-8-6.2 through R315-8-6.11 because alternative requirements will protect human health and the environment.
6.2 REQUIRED PROGRAMS
(a) Owners and operators subject to this section shall conduct a monitoring and response program as follows:
(1) Whenever hazardous constituents under R315-8-6.4, from a regulated unit are detected at the compliance point under R315-8-6.6, the owner or operator shall institute a compliance monitoring program under R315-8-6.10. Detected is defined as statistically significant evidence of contamination as described in R315-8-6.9(f);
(2) Whenever the groundwater protection standard under R315-8-6.3, is exceeded, the owner or operator shall institute a corrective action program under R315-8-6.11. "Exceeded" is defined as statistically significant evidence of increased contamination as described in R315-8-6.10(d);
(3) Whenever hazardous constituents under R315-8-6.4, from a regulated unit exceed concentration limits under R315-8-6.5 in groundwater between the compliance point under R315-8-6.6 and the downgradient facility property boundary, the owner or operator shall institute a corrective action program under R315-8-6.11; or
(4) In all other cases, the owner or operator shall institute a detection monitoring program under R315-8-6.9.
(b) The Executive Secretary will specify in the facility permit the specific elements of the monitoring and response program. The Executive Secretary may include one or more of the programs identified in R315-8- 6.2(a) in the facility permit as may be necessary to protect human health and the environment and will specify the circumstances under which each of the programs will be required. In deciding whether to require the owner or operator to be prepared to institute a particular program, the Executive Secretary will consider the potential adverse effects on human health and the environment that might occur before final administrative action on a permit modification application to incorporate this type of a program could be taken.
6.3 GROUNDWATER PROTECTION STANDARD
The owner or operator shall comply with conditions specified in the facility permit that are designed to ensure that hazardous constituents under R315-8-6.4 that are detected in the groundwater from a regulated unit do not exceed the concentration limits under R315-8-6.5 in the uppermost aquifer underlaying the waste management area beyond the point of compliance under R315-8-6.6 during the compliance period under R315-8-6.7. The Executive Secretary will establish this groundwater protection standard in the facility permit when hazardous constituents have been detected in the groundwater.
6.4 HAZARDOUS CONSTITUENTS
(a) The Executive Secretary will specify in the facility permit the hazardous constituents to which the groundwater protection standard of R315-8-6.3 applies. Hazardous constituents are constituents identified in R315-50- 10, which incorporates by reference 40 CFR 261, Appendix VIII, that have been detected in groundwater in the uppermost aquifer underlaying a regulated unit and that are reasonably expected to be in or derived from waste contained in a regulated unit, unless the Executive Secretary has excluded them under paragraph 8.6.4(b).
(b) The Executive Secretary will exclude an R315-50-10 constituent from the list of hazardous constituents specified in the facility permit if he finds that the constituent is not capable of posing a substantial present or potential hazard to human health or the environment. In deciding whether to grant an exemption, the Executive Secretary will consider the following:
(1) Potential adverse effects on groundwater quality, considering:
(i) The physical and chemical characteristics of the waste in the regulated unit, including its potential for migration;
(ii) The hydrogeological characteristics of the facility and surrounding land;
(iii) The quantity of groundwater and the direction of groundwater flow;
(iv) The proximity and withdrawal rates of groundwater users;
(v) The current and future uses of groundwater in the area;
(vi) The existing quality of groundwater, including other sources of contamination and their cumulative impact on the groundwater quality;
(vii) The potential for health risks caused by human exposure to waste constituents;
(viii) The potential damage to wildlife, crops, vegetation, and physical structures caused by exposure to waste constituents;
(ix) The persistence and permanence of the potential adverse effects; and
(2) Potential adverse effects on hydraulically-connected surface water quality, considering:
(i) The volume and physical and chemical characteristics of the waste in the regulated unit;
(ii) The hydrogeological characteristics of the facility and surrounding land;
(iii) The quantity and quality of groundwater and the direction of groundwater flow;
(iv) The patterns of rainfall in the region;
(v) The proximity of the regulated unit to surface waters;
(vi) The current and future uses of surface waters in the area and any water quality standards established for those surface waters;
(vii) The existing quality of surface water, including other sources of contamination and the cumulative impact on surface water quality;
(viii) The potential for health risks caused by human exposure to waste constituents;
(ix) The potential damage to wildlife, crops, vegetation, and physical structures caused by exposure to waste constituents; and
(x) The persistence and permanence of the potential adverse effects.
(c) In making any determination under R315-8-6.4(b) about the use of groundwater in the area around the facility, the Executive Secretary will consider any identification of underground sources of drinking water.
6.5 CONCENTRATION LIMITS
(a) The Executive Secretary will specify in the facility permit concentration limits in the groundwater for hazardous constituents established under R315-8-6.4. The concentration of a hazardous constituent:
(1) Shall not exceed the background level of that constituent in the groundwater at the time that limit is specified in the permit; or
(2) For any of the constituents listed in Table 1, shall not exceed the respective value given in that Table if the background level of the constituent is below the value given in Table 1; or
TABLE 1
Maximum Concentration of Constituents for Groundwater Protection
MAXIMUM
CONSTITUENT CONCENTRATION(1)
Arsenic 0.05
Barium 1.0
Cadmium 0.01
Chromium 0.05
Lead 0.05
Mercury 0.002
Selenium 0.01
Silver 0.05
Endrin (1,2,3,4,10,10-hexachloro-1,
7-epoxy-1,4,4a,5,6,7,8,
9a-octahydro-1, 4-endo,
endo-5,8-dimethano
naphthalene) 0.0002
Lindane (1,2,3,4,5,6,-hexachlorocyclohexane,
gamma isomer) 0.004
Methoxychlor (1,1,1-Trichloro-2,2-bis
(p-methoxyphenylethane) 0.1
Toxaphene (C10H10C18, Technical
chlorinated camphene,
67-69 percent chlorine) 0.005
2,4-D (2,4-Dichlorophenoxyacetic
acid) 0.1
2,4,5-TP Silvex (2,4,5-Trichlorophenoxypropionic
acid) 0.01
(1)Milligrams per liter
(3) Shall not exceed an alternate limit established by the Executive Secretary under R315-8- 6.5(b).
(b) The Executive Secretary will establish an alternate concentration limit for a hazardous constituent if they find that the constituent will not pose a substantial present or potential hazard to human health or the environment as long as the alternate concentration limit is not exceeded. In establishing alternate concentration limits, the Executive Secretary will consider the following factors:
(1) Potential adverse effects on groundwater quality, considering:
(i) The physical and chemical characteristics of the waste in the regulated unit, including its potential for migration;
(ii) The hydrogeological characteristics of the facility and surrounding land;
(iii) The quantity of groundwater and the direction of groundwater flow;
(iv) The proximity and withdrawal rates of groundwater users;
(v) The current and future uses of groundwater in the area;
(vi) The existing quality of groundwater, including other sources of contamination and their cumulative impact on the groundwater quality;
(vii) The potential for health risks caused by human exposure to waste constituents;
(viii) The potential damage to wildlife, crops, vegetation, and physical structures caused by exposure to waste constituents;
(ix) The persistence and permanence of the potential adverse effects; and
(2) Potential adverse effects on hydraulically connected surface water quality, considering:
(i) The volume and physical and chemical characteristics of the waste in the regulated unit;
(ii) The hydrogeological characteristics of the facility and surrounding land;
(iii) The quantity and quality of groundwater, and the direction of groundwater flow;
(iv) The patterns of rainfall in the region;
(v) The proximity of the regulated unit to surface waters;
(vi) The current and future uses of surface waters in the area and any water quality standards established for those surface waters;
(vii) The existing quality of surface water, including other sources of contamination and the cumulative impact on surface water quality;
(viii) The potential for health risks caused by human exposure to waste constituents;
(ix) The potential damage to wildlife, crops, vegetation, and physical structures caused by exposure to waste constituents; and
(x) The persistence and permanence of the potential adverse effects.
(c) In making any determination under R315-8-6.5(b) about the use of groundwater in the area around the facility the Board will consider any identification of underground sources of drinking water.
6.6 POINT OF COMPLIANCE
(a) The Executive Secretary will specify in the facility permit the point of compliance at which the groundwater protection standard of R315-8-6.3 applies and at which monitoring shall be conducted. The point of compliance is a vertical surface located at the hydraulically downgradient limit of the waste management area that extends down into the uppermost aquifer underlaying the regulated units.
(b) The waste management area is the limit projected in the horizontal plane of the area on which waste will be placed during the active life of a regulated unit.
(1) The waste management area includes horizontal space taken up by any liner, dike, or other barrier designed to contain waste in a regulated unit.
(2) If the facility contains more than one regulated unit, the waste management area is described by an imaginary line circumscribing the several regulated units.
6.7 COMPLIANCE PERIOD
(a) The Executive Secretary will specify in the facility permit the compliance period during which the groundwater protection standard of R315-8-6.3 applies. The compliance period is the number of years equal to the active life of the waste management area, including any waste management activity prior to permit and the closure period.
(b) The compliance period begins when the owner or operator initiates a compliance monitoring program meeting the requirements of R315-8-6.9.
(c) If the owner or operator is engaged in a corrective action program at the end of the compliance period specified in R315-8-6.7(a), the compliance period is extended until the owner or operator can demonstrate that the groundwater protection standard of R315-8-6.3 has not been exceeded for a period of three consecutive years.
6.8 GENERAL GROUNDWATER MONITORING REQUIREMENTS
The owner or operator shall comply with the following requirements for any groundwater monitoring program developed to satisfy R315-8-6.9, R315-8-6.10, or R315-8-6.11:
(a) The groundwater monitoring system shall consist of a sufficient number of wells, installed at appropriate locations and depths to yield groundwater samples from the uppermost aquifer that:
(1) Represent the quality of background water that has not been affected by leakage from a regulated unit;
(i) A determination of background quality may include sampling of wells that are not hydraulically upgradient of the waste management area where:
(A) hydrogeologic conditions do not allow the owner or operator to determine what wells are hydraulically upgradient; and
(B) Sampling at other wells will provide an indication of background groundwater quality that is representative or more representative than that provided by the upgradient wells;
(2) represent the quality of groundwater passing the point of compliance; and
(3) allow for the detection of contamination when hazardous waste or hazardous constituents have migrated from the waste management area to the uppermost aquifer.
(b) If a facility contains more than one regulated unit, separate groundwater monitoring systems are not required for each regulated unit provided that provisions for sampling the groundwater in the uppermost aquifer will enable detection and measurement at the compliance point of hazardous constituents from the regulated units that have entered the groundwater in the uppermost aquifer.
(c) All monitoring wells shall be cased in a manner that maintains the integrity of the monitoring well bore hole. This casing shall be screened or perforated and packed with gravel or sand, where necessary, to enable collection of groundwater samples. The annular space, i.e., the space between the bore hole and well casing, above the sampling depth shall be sealed to prevent contamination of samples and the groundwater.
(d) The groundwater monitoring program shall include consistent sampling and analysis procedures that are designed to ensure monitoring results that provide a reliable indication of groundwater quality below the waste management area. At a minimum the program shall include procedures and techniques for:
(1) Sample collection;
(2) Sample preservation and shipment;
(3) Analytical procedures; and
(4) Chain of custody control.
(e) The groundwater monitoring program shall include sampling and analytical methods that are appropriate for groundwater sampling and that accurately measure hazardous constituents in groundwater samples.
(f) The groundwater monitoring program shall include a determination of the groundwater surface elevation each time groundwater is sampled.
(g) In detection monitoring or where appropriate in compliance monitoring, data on each hazardous constituent specified in the permit will be collected from background wells and wells at the compliance point. The number and kinds of samples collected to establish background shall be appropriate for the form of statistical test employed, following generally accepted statistical principles. The sample size should be as large as necessary to ensure with reasonable confidence that a contaminant release to groundwater from a facility will be detected. The owner or operator will determine an appropriate sampling procedure and interval for each hazardous constituent listed in the facility permit which shall be specified in the unit permit upon approval by the Executive Secretary. This sampling procedure should be:
(1) a sequence of at least four samples, taken at an interval that assures, to the greatest extent technically feasible, that an independent sample is obtained, by reference to the uppermost aquifer's effective porosity, hydraulic conductivity, and hydraulic gradient, and the fate and transport characteristics of the potential contaminants; or
(2) an alternate sampling procedure proposed by the owner or operator and approved by the Executive Secretary.
(h) The owner or operator will specify one of the following statistical methods to be used in evaluating groundwater monitoring data for each hazardous constituent, upon approval by the Executive Secretary, will be specified in the unit permit. The statistical test chosen shall be conducted separately for each hazardous constituent in each well. Where practical quantification limits, pql's, are used in any of the following statistical procedures to comply with R315-8-6.8(i)(5), the pql shall be proposed by the owner or operator and approved by the Executive Secretary. Use of any of the following statistical methods shall be protective of human health and the environment and shall comply with the performance standards outlined in R315-8-6.8(i).
(1) a parametric analysis of variance, ANOVA, followed by multiple comparisons procedures to identify statistical significant evidence of contamination. The method shall include estimation and testing of the contrasts between each compliance well's mean and the background mean levels for each constituent;
(2) an analysis of variance, ANOVA, based on ranks followed by multiple comparisons procedures to identify statistical significant evidence of contamination. The method shall include estimation and testing of the contrasts between compliance well's median and the background median levels for each constituent;
(3) a tolerance or prediction interval procedure in which an interval for each constituent is established from the distribution of the background data, and the level of each constituent in each compliance well is compared to the upper tolerance or prediction limit;
(4) a control chart approach that gives control limits for each constituent;
(5) another statistical test method submitted by the owner or operator and approved by the Executive Secretary.
(i) Any statistical method chosen under R315-8-6.8(h) for specification in the unit permit shall comply with the following performance standards, as appropriate:
(1) The statistical method used to evaluate groundwater monitoring data shall be appropriate for the distribution of chemical parameters or hazardous constituents. If the distribution of the chemical parameters or hazardous constituents is shown by the owner or operator to be inappropriate for a normal theory test, then the data should be transformed or a distribution-free theory test should be used. If the distributions for the constituents differ, more than one statistical method may be needed.
(2) If an individual well comparison procedure is used to compare an individual compliance well constituent concentration with background constituent concentrations or a groundwater protection standard, the test shall be done at a Type I error level no less than 0.01 for each testing period. If a multiple comparisons procedure is used, the Type I experimentwise error rate for each testing period shall be no less than 0.05; however, the Type I error of no less than 0.01 for individual well comparisons shall be maintained. This performance standard does not apply to tolerance intervals, predictions intervals or control charts.
(3) If a control chart approach is used to evaluate groundwater monitoring data, the specific type of control chart and its associated parameter values shall be proposed by the owner or operator and approved by the Executive Secretary if he finds it to be protective of human health and the environment.
(4) If a tolerance interval or a prediction interval is used to evaluate groundwater monitoring data, the levels of confidence and, for tolerance intervals, the percentage of the population that the interval shall contain, shall be proposed by the owner or operator and approved by the Executive Secretary if he finds these parameters to be protective of human health and the environment. These parameters will be determined after considering the number of samples in the background data base, the data distribution, and the range of the concentration values for each constituent of concern.
(5) The statistical method shall account for data below the limit of detection with one or more statistical procedures that are protective of human health and the environment. Any practical quantification limit, pql, approved by the Executive Secretary under R315-8-6.8(h) that is used in the statistical method shall be the lowest concentration level that can be reliably achieved within specified limits of precision and accuracy during routine laboratory operating conditions that are available to the facility.
(6) If necessary, the statistical method shall include procedures to control or correct for seasonal and spatial variability as well as temporal correlation in the data.
(j) Groundwater monitoring data collected in accordance with R315-8-6.8(g) including actual levels of constituents shall be maintained in the facility operating record. The Executive Secretary will specify in the permit when the data shall be submitted for review.
6.9 DETECTION MONITORING PROGRAM
An owner or operator required to establish a detection monitoring program under this section shall, at a minimum, discharge the following responsibilities:
(a) The owner or operator shall monitor for indicator parameters, e.g., specific conductance, pH, total organic carbon, or total organic halogen, waste constituents, or reaction products that provide a reliable indication of the presence of hazardous constituents in groundwater. The Executive Secretary will specify the parameters or constituents to be monitored in the facility permit after considering the following factors:
(1) The types, quantities, and concentrations of constituents in wastes managed at the regulated unit;
(2) The mobility, stability, and persistence of waste constituents or their reaction products in the unsaturated zone beneath the waste management area;
(3) The detectability of indicator parameters, waste constituents, and reaction products in groundwater; and
(4) The concentrations or values and coefficients of variation of proposed monitoring parameters or constituents in the groundwater background.
(b) The owner or operator shall install a groundwater monitoring system at the compliance point as specified under R315-8-6.6. The groundwater monitoring system shall comply with R315-8-6.8(a)(2), (b), and (c).
(c) The owner or operator shall conduct a groundwater monitoring program for each chemical parameter and hazardous constituent specified in the permit pursuant to R315-8-6.9(a) in accordance with R315-8-6.9(g). The owner or operator shall maintain a record of groundwater analytical data as measured and in a form necessary for the determination of statistical significance under R315-8-6.8(h).
(d) The Executive Secretary will specify the frequencies for collecting samples and conducting statistical tests to determine whether there is statistically significant evidence of contamination for any parameter or hazardous constituent specified in the permit under R315-8-6.9(a) in accordance with R315-8-6.8(g). A sequence of at least four samples from each well, background and compliance wells, shall be collected at least semiannually during detection monitoring.
(e) The owner or operator shall determine the groundwater flow rate and direction in the uppermost aquifer at least annually.
(f) The owner or operator shall determine whether there is statistically significant evidence of contamination for any chemical parameter of hazardous constituent specified in the permit pursuant to R315-8-6.9(a) at a frequency specified under R315-8-6.9(d).
(1) In determining whether statistically significant evidence of contamination exists, the owner or operator shall use the method specified in the permit under R315-8-6.8(h). This method shall compare data collected at the compliance point to the background groundwater quality data.
(2) The owner or operator shall determine whether there is statistically significant evidence of contamination at each monitoring well as the compliance point within a reasonable period of time after completion of sampling. The Executive Secretary will specify in the facility permit what period of time is reasonable, after considering the complexity of the statistical test and the availability of laboratory facilities to perform the analysis of groundwater samples.
(g) If the owner or operator determines pursuant to R315-8-6.9(f) that there is statistically significant evidence of contamination for chemical parameters of hazardous constituents specified pursuant to R315-8-6.9(a) at any monitoring well at the compliance point, he shall:
(1) notify the Executive Secretary of this finding in writing within seven days. The notification shall indicate what chemical parameters or hazardous constituents have shown statistically significant evidence of contamination;
(2) immediately sample the groundwater in all monitoring wells and determine whether constituents in the list of R315-50-14, which incorporates by reference 40 CFR 264, Appendix IX, are present, and if so, in what concentration;
(3) for any R315-50-14, which incorporates by reference 40 CFR 264, Appendix IX, compounds found in the analysis pursuant to R315-8-6.9(g)(2), the owner or operator may resample within one month and repeat the analysis for these compounds detected. If the results for the second analysis confirm the initial results, then these constituents will form the basis for compliance monitoring. If the owner or operator does not resample for the compounds found pursuant to R315-8-6.9(g)(2), the hazardous constituents found during this initial R315-50-14, which incorporates by reference 40 CFR 264, Appendix IX, analysis will form the basis for compliance monitoring;
(4) within 90 days, submit to the Executive Secretary an application for a permit modification to establish a compliance monitoring program meeting the requirements of R315-8-6.10. The application shall include the following information;
(i) an identification of the concentration of any R315-50-14, which incorporates by reference 40 CFR 264, Appendix IX, constituent detected in the groundwater at each monitoring well at the compliance point;
(ii) any proposed changes to the groundwater monitoring system at the facility necessary to meet the requirements of R315-8-6.10;
(iii) any proposed additions or changes to the monitoring frequency, sampling and analysis procedures or methods, or statistical methods used at the facility necessary to meet the requirements of R315-8-6.10;
(iv) for each hazardous constituent detected at the compliance point, a proposed concentration limit under R315-8-6.10(a)(1) or (2), or a notice of intent to seek an alternate concentration limit under R315-8-6.5(b); and
(5) within 180 days, submit to the Executive Secretary:
(i) all data necessary to justify an alternate concentration limit sought under R315-8-6.5(b); and
(ii) an engineering feasibility plan for a corrective action program necessary to meet the requirement of R315-8-6.11, unless:
(A) all hazardous constituents identified under R315-8-6.9(g)(2) are listed in R315-8-6.5, Table 1 and their concentrations do not exceed their respective values given in that table; or
(B) the owner or operator has sought an alternate concentration limit under R315-8-6.5(b) for every hazardous constituent identified under R315-8-6.9(g)(2).
(6) If the owner or operator determines, pursuant to R315-8-6.9(f), that there is a statistically significant difference for chemical parameters or hazardous constituents specified pursuant to R315-8-6.9(a) at any monitoring well at the compliance point, he may demonstrate that a source other than a regulated unit caused the contamination or that the detection is an artifact caused by an error in sampling, analysis, or statistical evaluation or natural variation in the groundwater. The owner or operator may make a demonstration under R315-8-6.9(g)(6) in addition to, or in lieu of, submitting a permit modification application under R315-8-6.9(g)(4); however, the owner or operator is not relieved of the requirement to submit a permit modification application within the time specified in R315-8-6.9(g)(4) unless the demonstration made under R315-8-6.9(g)(6) successfully shows that a source other than the regulated unit caused the increase, or that the increase resulted from error in sampling, analysis, or evaluation. In making a demonstration under R315-8-6.9(g)(6), the owner or operator shall:
(i) notify the Executive Secretary in writing within seven days of determining statistically significant evidence of contamination at the compliance point that he intends to make a demonstration under this paragraph;
(ii) within 90 days, submit a report to the Executive Secretary which demonstrates that a source other than a regulated unit caused the contamination or that the contamination resulted from error in sampling, analysis, or evaluation;
(iii) within 90 days, submit to the Executive Secretary an application for a permit modification to make any appropriate changes to the detection monitoring program facility; and
(iv) continue to monitor in accordance with the detection monitoring program established under R315- 8-6.9.
(h) If the owner or operator determines that the detection monitoring program no longer satisfies the requirements of this section, he shall, within 90 days, submit an application for a permit modification to make any appropriate changes to the program.
6.10 COMPLIANCE MONITORING PROGRAM
An owner or operator required to establish a compliance monitoring program under this section shall, at a minimum, discharge the following responsibilities:
(a) The owner or operator shall monitor the groundwater to determine whether regulated units are in compliance with the groundwater protection standard under R315-8-6.3. The Executive Secretary will specify the groundwater protection standard in the facility permit including:
(1) A list of the hazardous constituents identified under R315-8-6.4;
(2) Concentration limits under R315-8-6.5 for each of those hazardous constituents;
(3) The compliance point under R315-8-6.6;
(4) The compliance period under R315-8-6.7.
(b) The owner or operator shall install a groundwater monitoring system at the compliance point as specified under R315-8-6.6. The groundwater monitoring system shall comply with R315-8-6.8(a)(2), (b) and (c).
(c) The Executive Secretary will specify the sampling procedures and statistical methods appropriate for the constituents and the facility, consistent with R315-8-6.8(g) and (h).
(1) The owner or operator shall conduct a sampling program for each chemical parameter or hazardous waste constituent in accordance with R315-8-6.8(g).
(2) The owner or operator shall record groundwater analytical data as measured and in form necessary for the determination of statistical significance under R315-8-6.8(h) for the compliance period of the facility.
(d) The owner or operator shall determine whether there is statistically significant evidence of increased contamination for any chemical parameter or hazardous constituent specified in the permit, pursuant to R315-8- 6.10(a), at a frequency specified under R315-8-6.10(f).
(1) In determining whether statistically significant evidence of increased contamination exists, the owner or operator shall use the method specified in the permit under R315-8-6.5. The method shall compare data collected at the compliance point to a concentration limit developed in accordance with R315-8-6.8(h).
(2) The owner or operator shall determine whether there is statistically significant evidence of increase contamination at each monitoring well at the compliance point within a reasonable time period after completion of sampling. The Executive Secretary will specify that time period in the facility permit, after considering the complexity of the statistical test and the availability of laboratory facilities to perform the analysis of groundwater samples.
(e) The owner or operator shall determine the groundwater flow rate and direction in the uppermost aquifer at least annually.
(f) The Executive Secretary will specify the frequencies for collecting samples and conducting statistical tests to determine statistically significant evidence of increased contamination in accordance with R315-8- 6.8(g). A sequence of at least four samples from each well, background and compliance wells, shall be collected at least semi-annually during the compliance period of the facility.
(g) The owner or operator shall analyze samples from all monitoring wells at the compliance point for all constituents contained in R315-50-14, which incorporates by reference 40 CFR, Appendix IX, at least annually to determine whether additional hazardous constituents are present in the uppermost aquifer and, if so, at what concentration, pursuant to procedures in R315-8-6.9(f). If the owner or operator finds R315-50-14, which incorporates by reference 40 CFR 264, Appendix IX, constituents in the groundwater that are not already identified in the permit as monitoring constituents, the owner or operator may resample within one month and repeat the R315-50-14, which incorporates by reference 40 CFR 264, Appendix IX, analysis. If the second analysis confirms the presence of new constituents, the owner or operator shall report the concentration of these additional constituents to the Executive Secretary within seven days after the completion of the second analysis and add them to the monitoring list. If the owner or operator chooses not to resample, then he shall report the concentrations of these additional constituents to the Executive Secretary within seven days after completion of the initial analysis and add them to the monitoring list.
(h) If the owner or operator determines pursuant to R315-8-6.10(d) that any concentration limits under R315-8-6.5 are being exceeded at any monitoring well at the point of compliance he shall:
(1) Notify the Executive Secretary of this finding in writing within seven days. The notification shall indicate which concentration limits have been exceeded;
(2) Submit to the Executive Secretary an application for a permit modification to establish a corrective action program meeting the requirements of R315-8-6.11, within 180 days, or within 90 days if an engineering feasibility study has been previously submitted to the Executive Secretary under R315-8-6.9(h)(5). The application shall at a minimum include the following information:
(i) A detailed description of corrective actions that will achieve compliance with the groundwater protection standard specified in the permit under R315-8-6.10(a); and
(ii) A plan for a groundwater monitoring program that will demonstrate the effectiveness of the corrective action. The groundwater monitoring program may be based on a compliance monitoring program developed to meet the requirements of this section.
(i) If the owner or operator determines, pursuant to R315-8-6.10(d), that the groundwater concentration limits under R315-8-6.10 are being exceeded at any monitoring well at the point of compliance, he may demonstrate that a source other than a regulated unit caused the contamination or that the detection is an artifact caused by an error in sampling, analysis, or statistical evaluation or natural variation in the groundwater. In making a demonstration under R315-8-6.10(i), the owner or operator shall:
(1) Notify the Executive Secretary in writing within seven days that he intends to make a demonstration under R315-8-6.10(i);
(2) Within 90 days, submit a report to the Executive Secretary which demonstrates that a source other than a regulated unit caused the standard to be exceeded or that the apparent noncompliance with the standards resulted from error in sampling, analysis, or evaluation;
(3) Within 90 days, submit to the Executive Secretary an application for a permit modification to make any appropriate changes to the compliance monitoring program at the facility; and
(4) Continue to monitor in accord with the compliance monitoring program established under this section.
(j) If the owner or operator determines that the compliance monitoring program no longer satisfies the requirements of this section, he shall within 90 days, submit an application for a permit modification to make any appropriate changes to the program.
6.11 CORRECTIVE ACTION PROGRAM
An owner or operator required to establish a corrective action program under this section shall, at a minimum, discharge the following responsibilities:
(a) The owner or operator shall take corrective action to ensure that regulated units are in compliance with the groundwater protection standard under R315-8-6.3. The Executive Secretary will specify the groundwater protection standard in the facility permit, including:
(1) A list of hazardous constituents identified under R315-8-6.4;
(2) Concentration limits under R315-8-6.5 for each of those hazardous constituents;
(3) The compliance point under R315-8-6.6; and
(4) The compliance period under R315-8-6.7.
(b) The owner or operator shall implement a corrective action program that prevents hazardous constituents from exceeding their respective concentration limits at the compliance point by removing the hazardous waste constituents or treating them in place. The permit will specify the specific measures that will be taken.
(c) The owner or operator shall begin corrective action within a reasonable time period after the groundwater protection standard is exceeded. The Executive Secretary will specify that time period in the facility permit. If a facility permit includes a corrective action program in addition to a compliance monitoring program, the permit will specify when the corrective action will begin and the requirement will operate in lieu of R315-8-6.10(i)(2).
(d) In conjunction with a corrective action program, the owner or operator shall establish and implement a groundwater monitoring program to demonstrate the effectiveness of the corrective action program. The monitoring program may be based on the requirements for a compliance monitoring program under R315-8-6.10 and shall be as effective as that program in determining compliance with the groundwater protection standard under R315-8-6.3 and in determining the success of a corrective action program under R315-8-6.11(e), where appropriate.
(e) In addition to the other requirements of this section, the owner or operator shall conduct a corrective action program to remove or treat in place any hazardous constituents under R315-8-6.4 that exceed concentration limits under R315-8-6.5 in groundwater:
(1) between the compliance point under R315-8-6.6 and the downgradient facility property boundary; and
(2) beyond the facility boundary, where necessary to protect human health and the environment, unless the owner or operator demonstrates to the satisfaction of the Executive Secretary that, despite the owner's or operator's best efforts, the owner or operator was unable to obtain the necessary permission to undertake the action. The owner or operator is not relieved of all responsibility to clean up a release that has migrated beyond the facility boundary where off-site access is denied. On-site measures to address the releases will be determined on a case-by-case basis.
(3) Corrective action measures under R315-8-6.11(e) shall be initiated and completed within a reasonable period of time considering the extent of contamination.
(4) Corrective action measures under this paragraph may be terminated once the concentration of hazardous constituents under R315-8-6.4 is reduced to levels below their respective concentration limits under R315-8- 6.5.
(f) The owner or operator shall continue corrective action measures during the compliance period to the extent necessary to ensure that the groundwater protection standard is not exceeded. If the owner or operator is conducting corrective action at the end of the compliance period, he shall continue that corrective action for as long as necessary to achieve compliance with the groundwater protection standard. The owner or operator may terminate corrective action measures taken beyond the period equal to the active life of the waste management area, including the closure period if he can demonstrate, based on data from the groundwater monitoring program under R315-8-6.11(d), that the groundwater protection standard of R315-8-6.3 has not been exceeded for a period of thr